Reverse Osmosis Systems: What to Know Before You Buy
Short answer: reverse osmosis is the most thorough treatment you can put under one kitchen sink, but it is a tool for specific problems, not an upgrade every household needs. It reduces many dissolved contaminants, it wastes water, and the only claims you can rely on are the ones printed on the system’s certification listing, usually NSF/ANSI 58.
Key facts
- How fine the membrane is: CDC puts the pore size of an RO filter at about 0.0001 micron (CDC, About Home Water Treatment Systems).
- What CDC says RO removes: lead, copper, chromium, chloride and sodium. It may also reduce arsenic, fluoride, radium, sulfate, calcium, magnesium, potassium, nitrate and phosphorus (CDC).
- Water waste: a typical point-of-use RO system makes 5 gallons or more of reject water per gallon of treated water, and some units up to 10 (EPA WaterSense).
- Efficient models: WaterSense-labeled RO systems must send 2.3 gallons or less to the drain per gallon produced. EPA says that saves more than 3,100 gallons a year compared with a typical unit.
- Membrane life: WaterSense-labeled systems must have a membrane that lasts at least one year (EPA WaterSense).
- PFAS: NSF verifies PFAS claims for RO under NSF/ANSI 58. Its 2022 update set the combined PFAS limit at 20 ppt, down from 70 ppt (NSF, September 2024).
- EPA’s own caution: WaterSense says it does not intend to promote RO for all applications, because other methods that use little or no water are sufficient in some cases.
How RO works
An RO system uses household water pressure to push water through a semi-permeable membrane. Treated water, called permeate, goes to a dedicated faucet. The rest, called concentrate or brine, carries away what the membrane rejected and goes down the drain. That reject stream is why RO uses more water than a standard filter.
Most home systems add other stages. NSF describes carbon prefilters ahead of an RO membrane as a common way to build a more efficient treatment train. The membrane itself is the part that does the heavy work on dissolved substances.
What RO can and cannot do
RO suits problems made of dissolved substances: lead, nitrate, some forms of arsenic, high total dissolved solids (TDS) and PFAS. EPA’s secondary standard for TDS is 500 mg/L, a guideline for taste and appearance. Minnesota’s Department of Health lists RO among the units that reduce arsenic and recommends choosing one certified by an independent organization.
Three limits are worth knowing:
- Claims are specific. CDC says RO “will remove some types of chemicals,” and tells you to check the label for the specific chemicals. A system certified for lead is not automatically certified for arsenic.
- It reduces helpful minerals too. CDC notes that filters can remove beneficial substances, and lists fluoride and calcium among what RO may reduce.
- It treats one tap. Point-of-use RO serves a single fixture, usually the kitchen sink.
RO compared with other options
| Option | What it does | Water use | Where it fits |
|---|---|---|---|
| Reverse osmosis | Membrane separates many dissolved chemicals | Highest; 5 or more gallons of reject per gallon made in a typical unit | Dissolved contaminants such as nitrate, some arsenic, PFAS, high TDS |
| Carbon filter (pitcher, fridge, under sink) | Carbon improves taste or reduces some contaminants such as lead, per CDC | Little or none | Taste, chlorine, and contaminants named on its listing |
| Distillation | Boils water and collects the steam | More energy and time than other systems, per CDC | Many chemicals, but CDC says bacteria can grow on coils when idle |
Certifications to look for
- NSF/ANSI 58: the standard for reverse osmosis systems. Manufacturers choose which claims to certify, and NSF verifies those claims.
- Other certifiers: EPA lists CSA Group, IAPMO R&T, NSF, UL and WQA as ANSI-accredited bodies for PFAS reduction. WQA’s Gold Seal says products are tested to recognized industry standards.
- EPA WaterSense: a separate label for efficiency. Labeled units must also show a baseline TDS reduction and be certified for any additional contaminant claims the maker makes.
How to check a certificate yourself
- Find the standard and certifier mark. You want NSF/ANSI 58 (or the same standard from another accredited certifier) on the package or data sheet.
- Copy the exact model number, including the membrane and filter cartridge part numbers.
- Look it up in the certifier’s directory. NSF: info.nsf.org/Certified/DWTU. WQA: find.wqa.org/find-products. IAPMO: pld.iapmo.org.
- Match the claims to your water test. If your problem is nitrate, arsenic, lead or PFAS, the listing must name it. A general “removes up to 99%” line on a box is not a claim.
- Look for the WaterSense label if water waste matters to you. Only labeled models are held to 2.3 gallons or less per gallon.
- Note the replacement schedule for the membrane and for each prefilter and postfilter.
If a model is not in the directory, treat its claims as unverified.
Reading a spec sheet
Manufacturers use different words for similar things. These are the lines that matter, and what each one tells you.
| Spec line | What it tells you | Benchmark from EPA or NSF |
|---|---|---|
| Certification standard | Which test the system passed | NSF/ANSI 58 for RO |
| Contaminant claims | What was actually verified | Must name your contaminant |
| Reject water per gallon made | How much goes down the drain | 5 or more is typical; 2.3 or less for WaterSense |
| TDS reduction | How well dissolved solids are cut | WaterSense requires a baseline level |
| Membrane life | How long before the main part is replaced | At least one year for WaterSense |
| Prefilter and postfilter schedule | Ongoing cost and upkeep | Follow the manufacturer |
A spec sheet that skips the first two rows is a sales sheet, not a test result.
What owning one involves
An RO system needs a drain connection and under-sink space. Plan for a replacement schedule on several parts. CDC says to follow manufacturer instructions for changing filters, to wear gloves when you do, and to wash your hands afterward. Keep records of dates.
Price comparisons should include replacement membranes and filters, and the added water bill from reject water. We do not list prices on this page. Our brand checks compare ownership costs for specific manufacturers.
When RO makes sense, and when it does not
It makes sense if your test shows a dissolved contaminant that a certified carbon filter does not address, such as nitrate, if your PFAS results are above what you want to drink, or if high TDS affects your water.
Consider something simpler if you only dislike chlorine taste, or if your utility’s annual water quality report shows no concern. CDC says that if your tap water has no harmful germs or chemicals, you may not need a home treatment system.
On a private well, test first. CDC says that if your well water contains harmful germs or chemicals, you should not drink it until it is treated, should use bottled or other safe water in the meantime, and should test again after treatment. RO is one possible step, not a replacement for disinfection or for a state-certified lab test. See our well water filter guide.
Questions people ask
Does reverse osmosis remove PFAS?
It can. EPA lists reverse osmosis as an effective home filter type for PFAS, and NSF verifies PFAS claims for RO systems under NSF/ANSI 58. Check that the exact model's listing names PFOA, PFOS or Total PFAS.
How much water does a reverse osmosis system waste?
EPA WaterSense says a typical point-of-use RO system produces 5 gallons or more of reject water per gallon of treated water, and some inefficient units up to 10. Labeled WaterSense models must send 2.3 gallons or less to the drain.
What certification should a reverse osmosis system have?
Look for NSF/ANSI 58, or an equivalent listing from another ANSI-accredited certifier such as WQA or IAPMO R&T, with claims for the contaminants you care about. EPA's WaterSense label adds water-efficiency and membrane-life criteria.
Does reverse osmosis remove everything from water?
No. CDC says RO removes some chemicals, including lead, copper, chromium, chloride and sodium, and may reduce others such as arsenic, nitrate and fluoride. It also reduces minerals like calcium and magnesium. Always check the label for specific claims.
Is reverse osmosis enough for well water with bacteria?
Do not rely on it. CDC says to avoid drinking well water that contains harmful germs or chemicals, use bottled or other safe water, treat the well, and test again afterward. Ask your health department about disinfection.
How often should I replace an RO membrane?
Follow the manufacturer's schedule. WaterSense requires labeled RO models to have a membrane life of at least one year, but your water quality and usage can change that.
Is reverse osmosis better than a carbon filter?
It depends on the contaminant. RO handles dissolved substances a basic carbon filter may not, but it wastes water. EPA WaterSense notes that filtration, which uses little or no water, is sufficient in some cases.
Sources
- EPA WaterSense: Point-of-Use Reverse Osmosis Systems
- CDC: About Home Water Treatment Systems
- CDC: About Choosing Home Water Filters
- CDC: Guidelines for Treating Well Water
- EPA: Reducing PFAS in Your Drinking Water with a Home Filter (fact sheet)
- EPA: Treatment Options for Removing PFAS from Drinking Water (fact sheet)
- NSF: Forever Chemicals and the Advancement of Filtration Standards
- NSF: Home Water Treatment System and Solutions
- EPA: Secondary Drinking Water Standards, Guidance for Nuisance Chemicals
- Minnesota Department of Health: Arsenic in Well Water
- WQA: Product Certification (Gold Seal)